No. ISO 13849-1 requires you to determine the required performance level (PLr) for each safety function — unless it is already specified by an applicable Type-C standard — but it does not mandate any specific method for doing so. The Annex A risk graph is only one informative (non-normative) example of such a method.
Evidence from the standard
Two points in EN ISO 13849-1:2023 make this explicit:
- The title of Annex A itself is “Guidance for the determination of required performance level (PLr)” — guidance, not a normative requirement. Annex A is an informative annex.
- Clause A.2 states verbatim: “This methodology to determine PLr is not mandatory.”
The Introduction further clarifies that the PLr must be determined as part of the risk assessment, but leaves the choice of method to the user.
What this means in practice
- Using the PLr from an applicable Type-C standard is perfectly acceptable — and in fact the preferred route when such a standard exists. Note, however, that a Type-C PLr acts as a floor: if your risk analysis identifies additional risks not covered by the Type-C standard’s assumptions, you must apply a higher PLr. Going lower than an applicable Type-C PLr is generally not acceptable — it would mean operating outside the established standards and would require extensive justification demonstrating an equal or higher effective level of safety under all conceivable circumstances. Not recommended.
- Using an alternative method is likewise unrestricted. Common examples:
- The IEC 62061 severity/exposure (Se × Cl) table, which provides PLr mappings directly. Use the PLr straight from that table — do not read the SIL and then convert to PLr via the SIL↔PL mapping table, since results may differ slightly for some Se/Cl combinations.
- The HaRMONY method (e.g. as implemented by Leuze) also provides PLr determination. Its use for PLr is rather uncommon in practice, but ISO 13849 gives no reason not to use it.
- Any other documented, defensible risk-estimation method.
The only hard requirement is that you actually determine a PLr — through a documented process — for every safety function, and that the designed safety function then meets or exceeds that PLr.
Source: EN ISO 13849-1:2023, Introduction & Annex A (esp. A.2)